How Much Insulation Do You Need for an Attic?

In short

ENERGY STAR recommends R30 to R60 for an uninsulated attic depending on climate zone, which is about 15 inches of fiberglass batts for R-49. To buy it, divide the attic area plus waste by the coverage on the package: a 40x28 foot attic (1,120 sq ft) at 88 sq ft per package needs 14 packages with 5 percent extra.

Two questions: how thick, and how much

Insulation planning has two parts. The first is how much R-value you want in the attic, which depends on your climate. The second is how many packages that takes to cover the area, which is simple division. Settle the first before the second.

R-value targets by climate zone

ENERGY STAR publishes recommended R-values for adding insulation to existing wood-framed homes, based on the 2021 International Energy Conservation Code. For an attic with no insulation, it recommends R30 in climate zone 1, R49 in zones 2 and 3, and R60 in zones 4 through 8. If you already have 3 to 4 inches, the targets are R25 in zone 1, R38 in zones 2 and 3, and R49 in zones 4 through 8. The University of Maryland Extension, citing U.S. Department of Energy minimums for existing Maryland homes, gives R-49 to R-60 for attics and calls R-60 ideal. Look up your county's climate zone, and check your local code, which may differ.

How deep is that?

The University of Maryland Extension says R-49 takes about 15 inches of fiberglass batts or about 13 inches of loose-fill cellulose. It also notes that batts must be installed without compression, loose-fill to the proper density to prevent settling, and that you can lay a second layer perpendicular to the first for added R-value. Keep insulation 3 inches from recessed lights, chimneys, flues and fan motors.

How much material: area divided by coverage

Each package lists its coverage on the label. Divide the area to insulate, minus openings and plus waste, by that coverage. The insulation calculator does this, and it has modes for a known area, walls (perimeter times height) or an attic (length times width).

packages = (area - openings) x (1 + waste) / coverage per package

Worked example: a 40 x 28 foot attic

The attic floor is 1,120 square feet. With 5 percent waste that is 1,176 square feet, and at 88 square feet per package, the order is 14 packages, which covers 1,232 square feet. With no waste you would need 13, and at 10 percent 14. A package that covers less area per bundle changes the count a lot, so use the number on the label of the product you are buying:

Coverage per packagePackages for the attic
40 sq ft per package30
64 sq ft per package19
88 sq ft per package14
106 sq ft per package12

Thicker batts usually cover less area per package, so check the label for the R-value you choose before you set the coverage.

Walls

For exterior walls in the calculator's walls mode, a 160 foot perimeter with 9 foot walls and 100 square feet of windows and doors is 1,340 square feet of net wall, which takes 16 packages at 88 square feet per package, or roughly 141 batts of 8 feet. Batt width should match the stud spacing: 15 inch batts for studs 16 inches on center, and 23 inch batts for 24 inches on center. Switching to the 23 inch batts changes the example to 16 packages at the same coverage per package, so check what each width covers. ENERGY STAR advises that when you replace siding you can add insulative sheathing, and that an uninsulated wood-frame wall should be blown with insulation first.

Air seal first

The University of Maryland Extension says insulation alone will not stop heat loss if air is leaking into the attic. Seal gaps around windows, doors and framing before you insulate, and look at plumbing stacks, recessed lights, wiring holes, ductwork and the tops of walls. Add weatherstripping around the attic hatch.

A quick cost check

At the calculator's placeholder price of $62 per package, the 14 packages for the attic cost about $868. Replace it with the real price of the R-value you choose, and remember that blown-in insulation is priced differently from batts.

Common mistakes

What else to consider

Attic work may also need baffles for ventilation, a vapor retarder in some climates, and safe access. Use the square footage calculator if the attic is not a simple rectangle.

Calculators for this guide

Frequently asked questions

What R-value do I need in my attic?

ENERGY STAR's table for existing homes gives R30 (zone 1), R49 (zones 2 and 3) and R60 (zones 4 to 8) for an uninsulated attic, and lower targets if you already have 3 to 4 inches. Your local code may differ.

How many inches of insulation is R-49?

The University of Maryland Extension says about 15 inches of fiberglass batts or about 13 inches of loose-fill cellulose.

How many packages of insulation do I need?

Divide the attic area plus waste by the package coverage. A 40x28 foot attic at 88 square feet per package with 5 percent waste needs 14 packages.

Sources and further reading